Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Year range
1.
Braz. dent. sci ; 17(1): 39-44, 2014. tab
Article in English | LILACS, BBO | ID: lil-728107

ABSTRACT

Objective: The aim of this study was to detect the influence of application mode of cleansing agents, on enamel and dentin during the adhesion process of a one-step self-etching adhesive system. Materials & Methods: 24 human molars were sectioned into halves along the long axis for enamel and dentin tests. The cleansing agents used were 3% hydrogen peroxide (group HP), anionic detergent (group AD), and antiseptic solution (group AS). In the experiment, these agents were applied with (active) and without friction (passive) on enamel and dentin surfaces. A one-step self-etching adhesive system (Clearfil S3 Bond) was applied on dental surface and composite resin cylinders were built using Tygon tubing molds. After 24 h, μSBS (microshear) test (1 mm/ min) and fracture analysis were performed. Results: There was no statistically significant difference in bond strength values regarding the application mode of cleansing agents for enamel and dentin (p ≥ 0.05). The use of antiseptic solution on enamel resulted in bond strength results significantly higher when compared with HP and AD (p = 0.014). Conclusions: Regarding bond strength to enamel and dentin using one-step self-etching adhesive system, application mode of the cleansing agents used in this study presented the same behavior. Antiseptic solution applied on enamel before the application of a one-step adhesive system increased bond strength performance


Objetivo: O objetivo deste estudo foi detectar a influência do modo de aplicação de agentes de limpeza, em esmalte e dentina durante o processo de adesão de um sistema adesivo auto-condicionante de passo único. Materiais e Métodos: 24 molares humanos foram seccionados em duas metades ao longo do eixo para testes de esmalte e dentina. Os agentes de limpeza utilizados foram: peróxido de hidrogênio 3% (grupo HP), detergente aniônico (grupo AD) e solução anti-séptica (grupo AS). No experimento, esses agentes foram aplicados com fricção (ativa) e sem fricção (passiva) em superfícies de esmalte e dentina. O sistema adesivo autocondicionante de um passo (Clearfil S3 Bond) foi aplicado na superfície dental e cilindros de resina composta foram construídas usando moldes (Tubos Tygon). Após 24 h, o teste de microcisalhamento (1 mm / min) e análise de fratura foram executados. Resultados: Não houve diferença estatisticamente significante nos valores de resistência de união em relação ao modo de aplicação de agentes de limpeza para esmalte e dentina (p ≥ 0,05). O uso de solução anti-séptica no esmalte resultou em resultados de resistência de união significativamente maior quando comparada com HP e AD (p = 0,014). Conclusões: Em relação à resistência de união ao esmalte e dentina utilizando sistema adesivo autocondicionante de passo único, o modo de aplicação dos agentes de limpeza utilizados neste estudo apresentaram o mesmo comportamento. A aplicação da solução anti-séptica aplicada sobre o esmalte antes da aplicação de um sistema adesivo de passo único apresentou melhor desempenho de resistência de união.


Subject(s)
Humans , Dental Cements , Hydrogen Peroxide
2.
São Paulo; s.n; 2008. 73 p. ilus, tab, graf, CD. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-538779

ABSTRACT

A presença de lesões de cárie localizadas em áreas de difícil acesso para realização de isolamento absoluto torna a contaminação do campo operatório um fator de grande importância para o sucesso de uma restauração adesiva, apesar da grande variedade de sistemas adesivos de uso simplificado existentes atualmente no mercado odontológico. Os estudos que envolvem contaminação por sangue existentes na literatura expõem diferentes métodos de manipulação do contaminante, quanto a adição ou não de um anticoagulante bem como quanto a possibilidade de armazenamento deste. Este trabalho teve como objetivo avaliar, através do ensaio de microcisalhamento, a metodologia mais adequada para obtenção, manipulação do sangue e a eficiência de diferentes substâncias de uso corrente no consultório odontológico para remoção do contaminante de uma superfície dental. No experimento 1 deste trabalho, 6 dentes foram seccionados ao meio, no sentido do longo eixo e distribuídos em grupos, de acordo com o período de armazenamento do sangue heparinizado (0 hora, 24horas, 7 dias) utilizado para contaminá-los previamente a aplicação do sistema adesivo autocondicionante de passo único (Clearfill S3 Bond). No expermiento 2, 18 dentes foram seccionados da mesma forma e distribuídos em grupos de acordo com o contaminante utilizado (ausência de contaminante, sangue fresco e sangue heparinizado-este utilizado pelo período máximo de tempo determinado pelo experimento anterior). No experimento 3 deste trabalho, 39 dentes foram seccionados e distribuídos em grupos de acordo com o agente de limpeza utilizado para remoção do contaminante (água oxigenada, Dakin e tergentol). Nesta fase foi avaliada a eficiência dos agentes de limpeza na restauração dos valores de adesão dos tecidos dentais aos valores obtidos em condições sem contaminação. Em todos ...


Although new self-etching adhesive systems provide a faster application due to a reduced number of components and application steps, the risk of contamination by oral fluids is not eliminated. Achieving good moisture control is a common problem in restorative dentistry. Blood contamination can occur especially when rubber dam isolation is not feasible, like carious lesions found near to gingival margin. To simulate gingival bleeding in laboratory study, some investigators have used freshly capillary blood, on the other hand other investigators have used venous blood sample with an anticoagulant. Among the studies that used venous blood with anticoagulant, some authors used this blood immediately after. However, other authors used the collected blood sample within one week. Based on this variety of blood manipulation, the aim of the present study was to investigate, in the first phase, the influence of storage period of the heparinized blood on microshear bond strength ofa 1-step self-etching adhesive system to enamel and dentin. In second phase, the influence of heparinized venous blood vs. fresh capillary blood on microshear bond strength of a 1-stepself-etching adhesive system to enamel and dentin was tested. In the third phase of this study the efficiency of different cleaning agents (Dakin’s solution, Tergentol and Hidrogen peroxide) on microshear bond strength of a 1-step self-etching adhesive system to enamel and dentin contaminated by blood was investigated. The results show that heparinized blood can be used to simulate gingival bleeding in laboratory study for up to 7 days without difference in its deleterious influence on adhesion tests. Contamination with fresh blood or heparinized blood resulted in lower values of adhesion, compared to enamel and dentin without contamination. All cleaning agents used in this study were efficient to recover the lost microshear bond strengths of blood contaminated enamel and dentin...


Subject(s)
Blood , Environmental Pollution , Dentin-Bonding Agents , Dentistry
3.
J. appl. oral sci ; 15(6): 486-491, Nov.-Dec. 2007. graf, tab
Article in English | LILACS | ID: lil-471104

ABSTRACT

This study evaluated the influence of curing tip distance, shade and filler particle size on Vickers microhardness (VHN) of composite resins. Two composites were tested: Filtek Z250 microhybrid (3M ESPE; shades A1 and A3.5) and Filtek Supreme nanofilled (3M ESPE; shades A1B and A3.5B). For each resin, 42 specimens (5 mm in diameter and 2 mm height) were prepared being 21 for each shade. The specimens were exposed using a 20-second exposure to a quartz-tungsten-halogen light source with an irradiance of approximately 560 mW/cm², at the following distances: 0 mm (surface contact), 6 mm and 12 mm from composite surface. Effectiveness of cure of different resins, shades and curing distances was determined by measuring the top and bottom hardness (VHN) of specimens using a digital microhardness tester (load: 50 g; dwell time: 45 seconds) 24 hours following curing. The hardness ratio was calculated by dividing VHN of the bottom surface by VHN of top surface. Three-way ANOVA and Tukey's post-hoc test (p<0.05) revealed statistically significant differences for all analyzed factors. As for top hardness, as microhardness ratio (bottom/top), the factors shade, distance and composite filler particle size exerted influence on resin curing. Lighter shade composites (A1 and A1B) showed higher hardness values. At 6 and 12 mm curing tip distances, hardness was lower when compared to 0 mm. The microhybrid composite resin presented higheer hardness, being its microhardness ratio satisfactory only at 0 mm for both shades and at 6 mm for the lighter shade. The nanofilled composite resin did not present satisfactory microhardness at the bottom while the microhybrid composite resin had higher hardness than the nanofilled. Composite's curing tip distance and shade can influence hardness.

4.
RPG rev. pos-grad ; 14(2): 168-173, abr.-jun. 2007. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-529473

ABSTRACT

Os pinos pré-fabricados têm sido freqüentemente indicados em restaurações de dentes tratados endodonticamente, principalmente pela rapidez de aplicação e preservação da estrutura dental. O objetivo deste estudo foi comparar a resistência à flexão de quatro tipos de pinos pré-fabricados, frente a uma força de compressão aplicada perpendicularmente ao seu longo eixo, na sua porção coronária. Quarenta raízes de caninos tratados endodonticamente e com seus condutos preparados para receber retentores foram divididas em quatro grupos: Grupo I, pinos de fibra de carbono (Angelus, Londrina, PR, Brasil); Grupo II, pinos de fibra de vidro (Angelus, Londrina, PR, Brasil); Grupo III, pinos de aço inoxidável (Angelus, Londrina, PR, Brasil); Grupo IV, pinos de titânio (Euro Post, Anthogyr, França). Os retentores foram cimentados com cimento resinoso (Enforce IV, Dentsply, Petrópolis, RJ, Brasil) e suas porções coronárias foram confeccionadas em resina composta fotoativa (Charisma, Heraeus Kulzer, Hanau, Alemanha). Após 24 horas de armazenamento em solução salina, os corpos de prova foram submetidos à carga compressiva numa Máquina Universal de Testes (Riehle), a uma velocidade de 0,5 mm/min até o dobramento dos retentores. As cargas máximas suportadas até o início do dobramento dos retentores foram registradas. Os resultados foram submetidos ao teste estatístico de análise de variância (ANOVA) e teste de Tukey (alfa = 0,05). Houve diferenças estatisticamente significantes com relação à resistência flexural entre os pinos de fibra vidro (21,96 + - 3,67) e titânio (38,95 + - 8,63) e entre os pinos de aço (46,48 + - 12,31) em relação aos de fibra de carbono (30,99 + - 6,61) e fibra de vidro (21,96 + - 3,67). Os pinos de aço e titânio apresentaram os melhores resultados, seguidos dos carbonos de fibra de carbono e fibra de vidro.


Subject(s)
In Vitro Techniques , Post and Core Technique , Tensile Strength , Tooth Root , Carbon , Dental Pins , Glass , Titanium
5.
RPG rev. pos-grad ; 9(1): 51-56, jan.-mar. 2002. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-391672

ABSTRACT

O objetivo deste estudo foi comparar a resistência à flexão de dois tipos de núcleos metálicos fundidos frente a uma força de compressão aplicada perpendicularmente ao seu longo eixo, na sua porção coronária. Foram utilizadas vinte raízes de caninos tratadas endodonticamente e preparadas para a confecção dos núcleos. Após a divisão aleatória das raízes em dois grupos de 10, as amostras foram numeradas e iniciou-se a modelagem direta dos núcleos. No primeiro grupo os núcleos foram fundidos em liga de cobre-alumínio (Duracast MS) e, no segundo, os núcleos foram fundidos em liga de prata-estanho (Pratalloy) e combinados com pinos pré-fabricados de aço inoxidável (FKG), sendo ambos posteriormente cimentados com cimento de fosfato de zinco. Vinte e quatro horas após a cimentação, os corpos-de-prova foram submetidos a carga compressiva numa máquina universal de testes (Kratos), a uma velocidade de 0,5 mm/min até o dobramento dos núcleos. As cargas máximas suportadas até o início do dobramento do núcleo foram registradas e calculadas com a área de cada núcleo. Os dados foram submetidos a análise estatística através do teste t de Student (p = 0,2887). Os resultados permitiram concluir que não houve diferença estatística significante entre os dois grupos, não existindo evidências para rejeitar a hipótese de igualdade entre as médias de carga máxima (as médias foram consideradas iguais)


Subject(s)
Dental Alloys , In Vitro Techniques , Post and Core Technique , Compressive Strength , Cuspid , Dental Pins , Pliability
SELECTION OF CITATIONS
SEARCH DETAIL